歡迎來到匠仁醫療設備有限公司網站!
內窺鏡作為醫療與工業檢測領域的關鍵設備,其精密光學系統與機械結構對維修工具提出嚴苛要求。維修過程需結合電子檢測、光學調試及機械校準等多學科技術,使用專業化工具保障設備恢復原始性能。以下從功能維度解析內窺鏡維修的核心工具及其應用場景。
As a key equipment in the fields of medical and industrial testing, endoscopes have strict requirements for maintenance tools due to their precise optical systems and mechanical structures. The maintenance process requires a combination of multidisciplinary technologies such as electronic testing, optical debugging, and mechanical calibration, and the use of specialized tools to ensure that the equipment is restored to its original performance. The following analyzes the core tools and their application scenarios for endoscopic maintenance from a functional perspective.
一、光學系統檢修工具
1、 Optical system maintenance tool
冷光源測試儀:
Cold light source tester:
用于檢測氙燈或LED光源的色溫、照度及光譜分布。設備通過積分球采集光線數據,可診斷光源老化程度,當色溫偏差超過±500K或照度衰減至初始值70%以下時,需更換燈組模塊。
Used to detect the color temperature, illuminance, and spectral distribution of xenon lamps or LED light sources. The device collects light data through an integrating sphere to diagnose the degree of aging of the light source. When the color temperature deviation exceeds ± 500K or the illuminance attenuates to below 70% of the initial value, the lamp module needs to be replaced.
光纖導光束檢測儀:
Fiber optic guided beam detector:
采用光功率計測量導光束傳輸效率,正常值應≥85%。對于彎曲半徑過小或受壓變形的導光束,可通過顯微鏡觀察纖芯斷裂情況,斷裂點超過3處即需整體更換。
Using an optical power meter to measure the transmission efficiency of the guide beam, the normal value should be ≥ 85%. For guide beams with a bending radius that is too small or deformed under pressure, the fiber core fracture can be observed under a microscope, and if there are more than 3 fracture points, they need to be replaced as a whole.
鏡面擦拭套裝:
Mirror wiping kit:
包含異丙醇清洗劑、無塵棉簽與鏡頭紙,用于清除物鏡、目鏡表面的油污與劃痕。對于頑固污漬,需使用CO?雪清洗機進行非接觸式清潔,避免損傷鍍膜層。
Contains isopropanol cleaning agent, dust-free cotton swabs, and lens paper, used to remove oil stains and scratches on the surface of objective lenses and eyepieces. For stubborn stains, a CO snow cleaner should be used for non-contact cleaning to avoid damaging the coating layer.
二、電子系統診斷設備
2、 Electronic system diagnostic equipment
示波器與邏輯分析儀:
Oscilloscope and Logic Analyzer:
聯合使用可捕獲圖像傳感器輸出的LVDS信號波形,通過眼圖分析判斷信號完整性。當上升沿時間超過1ns或噪聲容限低于200mV時,需檢查柔性線路板焊接質量。
Combine the captured LVDS signal waveform output by the image sensor and determine signal integrity through eye diagram analysis. When the rising edge time exceeds 1ns or the noise tolerance is below 200mV, the welding quality of the flexible circuit board needs to be checked.
CCD/CMOS測試卡:
CCD/CMOS test card:
生成標準分辨率圖卡與灰階卡,配合亮度計檢測成像單元的MTF(調制傳遞函數)。若中心區域MTF@50lp/mm低于30%,需重新調整傳感器與鏡頭的對焦精度。
Generate standard resolution image cards and grayscale cards, and use a brightness meter to detect the MTF (Modulation Transfer Function) of the imaging unit. If the central area MTF@50lp /If the mm is less than 30%, the focusing accuracy of the sensor and lens needs to be readjusted.
靜電放電模擬器:
Electrostatic discharge simulator:
模擬人體8kV接觸放電與15kV空氣放電場景,驗證主機電路的ESD防護能力。關鍵接口需通過IEC 61000-4-2四級測試標準,確保醫療環境下的使用安全性。
Simulate human 8kV contact discharge and 15kV air discharge scenarios to verify the ESD protection capability of the host circuit. Key interfaces must pass the IEC 61000-4-2 Level 4 testing standard to ensure safety in medical environments.
三、機械結構維修器具
3、 Mechanical structure maintenance equipment
內窺鏡角度調節器:
Endoscope angle adjuster:
采用六軸力傳感器與伺服電機系統,可精確復現彎曲部的蛇形運動。通過捕捉每個關節的扭矩曲線,診斷鋼絲繩斷裂或滑輪磨損故障,角度偏差超過5°即需維修。
By using a six axis force sensor and servo motor system, the serpentine motion of the bending part can be accurately reproduced. By capturing the torque curve of each joint, diagnose faults such as wire rope breakage or pulley wear, and repair if the angle deviation exceeds 5 °.
激光對中儀:
Laser centering device:
用于校準插入管的直線度,測量精度達0.01mm/m。對于直徑8mm以上的工業內窺鏡,彎曲段直線度誤差需控制在0.5mm以內,避免檢測時產生視覺盲區。
Used to calibrate the straightness of the insertion tube, with a measurement accuracy of 0.01mm/m. For industrial endoscopes with a diameter of over 8mm, the straightness error of the curved section should be controlled within 0.5mm to avoid visual blind spots during inspection.
密封性測試裝置:
Sealing testing device:
通過正壓(50kPa)與負壓(-30kPa)雙向檢測,確認先端部防水等級。使用熒光檢漏劑浸泡后,UV燈照射下無泄漏點方可重新封裝,確保設備滿足IP67防護要求。
Confirm the waterproof level of the tip by bidirectional detection of positive pressure (50kPa) and negative pressure (-30kPa). After soaking in fluorescent leak detector, the equipment can only be repackaged after there are no leakage points under UV light irradiation to ensure that it meets IP67 protection requirements.
四、專用校準與軟件工具
4、 Specialized calibration and software tools
幾何畸變校正卡:
Geometric distortion correction card:
印制標準網格圖案,配合圖像處理算法修正鏡頭畸變。醫療內窺鏡需將畸變率控制在10%以內,工業檢測設備則要求≤2%,保障測量數據的準確性。
Print standard grid patterns and use image processing algorithms to correct lens distortion. Medical endoscopes need to control the distortion rate within 10%, while industrial testing equipment requires ≤ 2% to ensure the accuracy of measurement data.
白平衡測試卡:
White Balance Test Card:
提供24色標準色塊,通過光譜儀采集數據生成校正矩陣。在4000K色溫環境下,色溫誤差需小于±200K,確保不同光源條件下的色彩還原一致性。
Provide 24 standard color blocks, collect data through a spectrometer to generate a calibration matrix. In a 4000K color temperature environment, the color temperature error should be less than ± 200K to ensure consistency in color reproduction under different light source conditions.
固件燒錄器:
Firmware burner:
支持JTAG與SWD協議,可升級主機MCU與FPGA程序。對于具備圖像增強功能的內窺鏡,需定期更新降噪算法,提升低照度環境下的成像清晰度。
Supports JTAG and SWD protocols, and can upgrade host MCU and FPGA programs. For endoscopes with image enhancement capabilities, it is necessary to regularly update noise reduction algorithms to improve imaging clarity in low light environments.
內窺鏡設備維修需構建光學、電子、機械三維檢測體系,工具選型直接影響維修質量。隨著4K成像與AI輔助診斷技術的發展,維修工具正向高精度、集成化方向演進,例如結合機器視覺的自動對焦校準臺,已將維修效率提升40%。未來,模塊化維修工具包將成為主流,助力工程師快速定位并解決復雜故障。
The maintenance of endoscopic equipment requires the construction of an optical, electronic, and mechanical three-dimensional detection system, and the selection of tools directly affects the quality of maintenance. With the development of 4K imaging and AI assisted diagnostic technology, maintenance tools are evolving towards high precision and integration. For example, the automatic focus calibration table combined with machine vision has increased maintenance efficiency by 40%. In the future, modular maintenance toolkits will become mainstream, helping engineers quickly locate and solve complex faults.
本文由內窺鏡設備維修友情奉獻.更多有關的知識請點擊:http://www.cnxgtzyj.cn我們將會對您提出的疑問進行詳細的解答,歡迎您登錄網站留言.
This article is a friendly contribution from the maintenance of endoscopic equipment For more information, please click: http://www.cnxgtzyj.cn We will provide detailed answers to your questions. You are welcome to log in to our website and leave a message
樊經理:13153199508 李經理:13873135765
公司地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室 湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室
備案號:魯ICP備2023027194號-1 魯公網安備 37010402441281號